Fuel Cell Test Cooling System
Product Description
The hydrogen fuel cell test cooling system can provide a stable test platform for fuel cell engines.
It is dedicated to the performance test of vehicle fuel cell engines. It consists of hydrogen supply system, load system, motor drive system, control system, safety system, etc.
The high-pressure hydrogen system supplies hydrogen to the fuel cell engine.
The engine outputs electrical energy, which is converted into rotary mechanical energy by a DC / DC converter and a motor to drive the dynamometer.
The dynamometer is both a load and a dynamic measurement device.
The hydrogen fuel cell test cooling system can provide a stable test platform for fuel cell engines.
It is dedicated to the performance test of vehicle fuel cell engines. It consists of hydrogen supply system, load system, motor drive system, control system, safety system, etc.
The high-pressure hydrogen system supplies hydrogen to the fuel cell engine.
The engine outputs electrical energy, which is converted into rotary mechanical energy by a DC / DC converter and a motor to drive the dynamometer.
The dynamometer is both a load and a dynamic measurement device.
WE APPLY THE CONTROLLER DEVELOPED BY SANWOOD
parameter
Model | SM-455 SM-455W |
SM-475 SM-475W |
SM-4A10 SM-4A10W |
SM-4A15 SM-4A15W |
SM-4A25 SM-4A25W |
SM-4A38W | SM-4A60W | |
Temp Range | -40℃~+100℃ | |||||||
Temperature control precision | ±0.5℃ | |||||||
Temperature feedback | Pt100 | |||||||
Temperature display | 0.01k | |||||||
Flow rate output | 1~10 L/min | 1~25 L/min | 1~25 L/min | 1~40 L/min | 1~40 L/min | 5~50 L/min | 5~50L/min | |
Flow description | / | When the temp. is below -30℃, | When the temp. is below-30℃, | |||||
the maximum flow rate is 25L/min. | the maximum flow rate is 30L/min. | |||||||
Flow rate accuracy | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2L/min | |
Pressure display | Adopt the Jeffron pressure sensor, the touch screen display the pressure, can carry on the pressure control adjustment. | |||||||
Heating power | 5.5kW | 7.5kW | 10kW | 10kW | 15kW | 25kW | 38kW | |
Optional 15kW | Optional 25kW | Optional 38kW | Optional 60kW | |||||
Cooling capacity |
100℃ | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW |
20℃ | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW | |
0℃ | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW | |
-20℃ | 2.8kW | 4.5kW | 6kW | 10kW | 16kW | 25kW | 35kW | |
-35℃ | 1.2kW | 1.8kW | 2.5kW | 4kW | 6.5kW | 10kW | 15kW | |
Compression | Emerson Valley Wheel Compressor | |||||||
Expansion valve/solenoid valve | Emerson / Danfoss thermal expansion valve | |||||||
Oil distributor | Emerson | |||||||
Dry filter, Pressure control | Emerson / Danvers | |||||||
Evaporator | Danfoss/KAORI plate heat exchanger | |||||||
Input,Display | Siemens 7-inch color touch screen \ Siemens s7-1200 PLC controller | |||||||
Program edit | 10 procedures may be prepared, each of which may be composed of 40 steps | |||||||
Communication | CAN communication bus | |||||||
Safety protection | Self-diagnosis function; freezer overload protection; high pressure pressure switch, overload relay, thermal protection device, low liquid level protection, high temperature protection, sensor fault protection, etc. | |||||||
Closed circulation system |
The whole system is a fully enclosed system. There is no oil mist at high temperature, and low temperature does not absorb moisture in the air. The system does not increase the pressure due to high temperature during operation, and the heat medium is automatically replenished at low temperature. | |||||||
refrigerant | R404A/ R507C | |||||||
Connection size | G3/4 | G3/4 | G3/4 | G3/4 | G3/4 | G3/4 | G3/4 | |
Cooling water@25C | 1100L/H | 1500L/H | 2000L/H | 2800L/H | 4500L/H | 7000L/H | 12000L/H | |
Condenser(W) | Tube type heat exchanger (Paris/Shenshi) | |||||||
Condenser(A) | Copper tube aluminum finned heat exchanger (upward wind) | |||||||
Power 380V50HZ | 12kW max | 15kW max | 20kW max | 29kW max | 42kW max | 58kW max | 84kW max | |
Dimension(W) cm | 55*95*175 | 55*95*175 | 55*95*175 | 70*100*175 | 80*120*185 | 100*150*185 | 145*205*205 | |
Dimension(A) cm | 55*95*175 | 55*95*175 | 70*100*175 | 80*120*185 | 100*150*185 | |||
Weight (water cooling) | 250kg | 280kg | 320kg | 360kg | 620kg | 890kg | 1300kg | |
Optional | 220V 60HZ Three phase 400V 50HZ Three phase 440V 60HZ Three phase | |||||||
Optional | Extend to -40~+135℃ | |||||||
Optional | Higher precision control of temperature, flow and pressure | |||||||
Optional | Automatic antifreeze filling system | |||||||
Optional | Automatic antifreeze filling system |